Application,Features: |
Measuring the volume of cold potable water passing throught the pipeline. Volumetric meter,on principle of piston rotation,accurate measurement,easy and long term clear reading etc. |
Working Condition: |
water temperature:≤40℃ water pressure:≤1Mpa Maximum Permissible Error a)in the lower zone from Qmin inclusive up to but excluding Qt is ±5% b)in the upper zone from Qt inclusive up to and incloding Qs is ±2% |
LXH-15~25 Main Technical Data
TYPE |
Size mm |
Class |
qs Max.Flaw |
qp Nominal Flow |
qt Transitional Flow |
qmin Min.Flow |
Min.Reading |
Max.Reading |
m3/h |
m3 |
LXH-15 |
15 |
C |
3 |
1.5 |
0.0025 |
0.015 |
0.00002 |
9999 |
D |
0.01725 |
0.01125 |
LXH-20 |
20 |
C |
5 |
2.5 |
0.0375 |
0.025 |
0.00002 |
9999 |
D |
0.02875 |
0.01875 |
Dimensions and Weight:
Type |
Size |
Length L |
Width B |
Height H |
Connecting Thread D |
Weight Kg |
mm |
LXH-15 |
15 |
115 |
91 |
91 |
G 3/4B |
0.95 |
LXH-20 |
20 |
130 |
96 |
96 |
G 1B |
1.15 |
LXH-15E~25E Main Technical Data
TYPE |
Size mm |
Class |
qs Max.Flaw |
qp Nominal Flow |
qt Transitional Flow |
qmin Min.Flow |
Min.Reading |
Max.Reading |
m3/h |
m3 |
LXH-15E |
15 |
C |
3 |
1.5 |
0.0025 |
0.015 |
0.00005 |
99999 |
D |
0.01725 |
0.01125 |
LXH-20E |
20 |
C |
5 |
2.5 |
0.0375 |
0.025 |
0.00005 |
99999 |
D |
0.02875 |
0.01875 |
Dimensions and Weight:
Type |
Size |
Length L |
Width B |
Height H |
Connecting Thread D |
Weight Kg |
mm |
LXH-15E |
15 |
165 |
95 |
115 |
G 3/4B |
1.45 |
LXH-20E |
20 |
190 |
100 |
121 |
G 1B |
1.8 | |